Technical Specs

Use this page if you need to know whether AAW Lab hardware fits your board, software, or experiment setup.

Item AAW sEMG Flex AAW sEMG Wireless
Positioning General sEMG analog front end Wireless sEMG acquisition kit
Best for Arduino / ESP32 / STM32 / oscilloscope / external ADC Browser waveform, multi-Edge wireless capture
Electrode style Wet leads, dry leads, onboard dry electrodes Edge onboard dry electrodes
Output Analog voltage Dongle USB serial, browser console, BLE envelope
Built-in ADC No Yes
Wireless No Yes
Raw EMG Acquired by your ADC Dongle serial
BLE data N/A Envelope data
Power Low-noise 5 V Edge battery; Dongle USB
Output range About 0–3.3 V Browser / serial data
Mid-rail reference About 1.65 V, VREF available Handled internally
Sampling Recommended >= 1000 Hz, minimum 800 Hz Target 3000 Hz
Medical use No No
Flex pin Connect to Notes
5V Low-noise 5 V power Battery or isolated power is recommended for first human-connected tests.
G ADC / MCU / oscilloscope ground Must share ground with the acquisition device.
S ADC input EMG analog output, about 0–3.3 V, centered near 1.65 V.
VREF / R Optional ADC input Mid-rail reference. For stable analysis, sample both S and VREF and compute S - VREF.

In examples, OUT maps to Flex S, VCC maps to 5V, and GND maps to G.

Item Notes
Edge Onboard dry electrodes, sEMG front end, wireless MCU, LiPo battery.
Dongle USB receiver. No battery. Must stay connected to the host.
Multi-device Up to 4 Edge devices per Dongle.
Sync recommendation Use one Dongle for multiple Edge devices when possible.
Raw data Dongle serial link.
BLE Mainly envelope data.
Charging Edge usually runs about 60–90 min after full charge. The switch needs to be on for charging. Charging starts about 3 min after USB is connected.
LED Main LED blue means normal operation; yellow blinking usually means low battery. The Type-C blue LED is not a full-charge indicator.
  • First verify motion-related change: relaxed low, activated high, relaxed low again.
  • For Flex, start from 1000 Hz; do not go below 800 Hz for typical tests.
  • ESP32 built-in ADC is useful for quick validation, but external ADC or STM32 ADC + DMA is better for repeatable analysis.
  • For Flex analysis, sampling both S and VREF helps remove baseline drift.
  • For Wireless raw EMG, use the Dongle serial link instead of treating BLE envelope as raw data.
  • Not for medical diagnosis, treatment, monitoring, or safety-critical use.
  • Use battery or safe isolated power for human-connected experiments.
  • Avoid connecting the body to mains-referenced equipment with unclear grounding.