Use this page if you need to know whether AAW Lab hardware fits your board, software, or experiment setup.
| Item |
AAW sEMG Flex |
AAW sEMG Wireless |
| Positioning |
General sEMG analog front end |
Wireless sEMG acquisition kit |
| Best for |
Arduino / ESP32 / STM32 / oscilloscope / external ADC |
Browser waveform, multi-Edge wireless capture |
| Electrode style |
Wet leads, dry leads, onboard dry electrodes |
Edge onboard dry electrodes |
| Output |
Analog voltage |
Dongle USB serial, browser console, BLE envelope |
| Built-in ADC |
No |
Yes |
| Wireless |
No |
Yes |
| Raw EMG |
Acquired by your ADC |
Dongle serial |
| BLE data |
N/A |
Envelope data |
| Power |
Low-noise 5 V |
Edge battery; Dongle USB |
| Output range |
About 0–3.3 V |
Browser / serial data |
| Mid-rail reference |
About 1.65 V, VREF available |
Handled internally |
| Sampling |
Recommended >= 1000 Hz, minimum 800 Hz |
Target 3000 Hz |
| Medical use |
No |
No |
| Flex pin |
Connect to |
Notes |
5V |
Low-noise 5 V power |
Battery or isolated power is recommended for first human-connected tests. |
G |
ADC / MCU / oscilloscope ground |
Must share ground with the acquisition device. |
S |
ADC input |
EMG analog output, about 0–3.3 V, centered near 1.65 V. |
VREF / R |
Optional ADC input |
Mid-rail reference. For stable analysis, sample both S and VREF and compute S - VREF. |
In examples, OUT maps to Flex S, VCC maps to 5V, and GND maps to G.
| Item |
Notes |
| Edge |
Onboard dry electrodes, sEMG front end, wireless MCU, LiPo battery. |
| Dongle |
USB receiver. No battery. Must stay connected to the host. |
| Multi-device |
Up to 4 Edge devices per Dongle. |
| Sync recommendation |
Use one Dongle for multiple Edge devices when possible. |
| Raw data |
Dongle serial link. |
| BLE |
Mainly envelope data. |
| Charging |
Edge usually runs about 60–90 min after full charge. The switch needs to be on for charging. Charging starts about 3 min after USB is connected. |
| LED |
Main LED blue means normal operation; yellow blinking usually means low battery. The Type-C blue LED is not a full-charge indicator. |
- First verify motion-related change: relaxed low, activated high, relaxed low again.
- For Flex, start from
1000 Hz; do not go below 800 Hz for typical tests.
- ESP32 built-in ADC is useful for quick validation, but external ADC or STM32 ADC + DMA is better for repeatable analysis.
- For Flex analysis, sampling both
S and VREF helps remove baseline drift.
- For Wireless raw EMG, use the Dongle serial link instead of treating BLE envelope as raw data.
- Not for medical diagnosis, treatment, monitoring, or safety-critical use.
- Use battery or safe isolated power for human-connected experiments.
- Avoid connecting the body to mains-referenced equipment with unclear grounding.