Electrode Placement
For AAW onboard dry electrodes, the + / VREF / - electrode layout is already fixed on the board. Place the electrode area over the muscle belly, keep stable pressure with a strap, and compare relaxed vs contracted states.
Lead electrodes are different: wet electrodes or dry lead electrodes are separate pads, so you must place IN+, IN-, and REF one by one.
Onboard Dry Electrodes
Section titled “Onboard Dry Electrodes”- Find the forearm muscle belly that becomes firm when you clench or bend the wrist.
- Place the onboard electrode area over that muscle belly.
- Keep all three contacts touching the skin.
- Use a strap or fixture; do not press the board by hand during the test.
Lead Electrodes
Section titled “Lead Electrodes”For wet electrodes or dry lead electrodes, place two measurement electrodes along the target muscle direction and place the reference electrode on a nearby bony or low-muscle-activity area.
Good placement is not just anatomy. It also depends on stable contact, low movement, and a clean power setup.
- Onboard dry electrodes are mechanically fixed; find the muscle belly and keep stable contact.
- Lead electrodes require separate
IN+,IN-, andREFplacement. - Keep the wire motion small.
- Compare relaxed and contracted states.
- Move the electrodes slightly if the signal does not react.
For AAW Lab modules, follow the shorter Quick Start workflow.